Technical data
stroke (stroke increments 30 mm) | 60 - 1200 mm |
temperature range | 0 - 60 °C |
weight basic slide unit (60 mm stroke) | 6.2 kg |
weight increase (per 60 mm stroke) | 0.63 kg |
weight slide (160 mm long) | 2.5 kg |
possible spindle pitch | 5/10/16 mm |
repeat accuracy | +/- 0.02 mm |
process accuracy (at 500 mm stroke) | <= 0.04 mm |
spindle pitch error (at 300 mm stroke) | <= 0.05 mm |
load rating linear guide system dyn./stat. | 29/48 kN |
geometrical moment of inertia of the basic body | Ix 424.993 mm4 / Iy 3.039.568 mm4 |
basic friction torque | 0.2 Nm |
Load information

C1 | 3000 N |
C2 | 3000 N |
Faxial | 2000 N |
Mx | 210 Nm |
My | 180 Nm |
Mz | 210 Nm |
Motor assembly variants






The motors are attached either directly via flange and coupling or via almost backlash-free belt gear. Different attachment versions and gear ratios are available. Attachment type and gear ratio can be changed easily even subsequently.
gear ratio | possible variants |
---|---|
i = 1:1 | 1 - 5 |
i = 2:1 | 1 - 4 |
i = 2,5:1 | 1 - 4 |
profiLINE 115 - Accessories
XY-assembly

Clamping strips

A | B | C | D |
134 | 150 | 14.3 | M6 |
CAD data |
Motor assembly variants |
Accessories |
Operating Manual |
Ihr Berater:

Günter Walenta
T: +49 7723 / 925 - 133
F: +49 7723 / 925 - 190